Conformal Coating Selection Guide
Key: 1 – Outstanding 2 – Excellent 3 – Good 4 – Fair NA – Not Available
Konform SR | Konform SR MV | Konform SR HV | Konform AR | Konform LED | |
Resistance | |||||
Temperature Resistance | 1 | 1 | 1 | 2 | 1 |
Abrasion Resistance | 4 | 4 | 4 | 1 | 4 |
Acid Resistance | 2 | 2 | 2 | 1 | 2 |
Solvent Resistance | 2 | 2 | 2 | 3 | 2 |
Humidity Resistance | 1 | 1 | 1 | 1 | 1 |
Underwriters Laboratories | |||||
Water Submersible Per UL | X | X | X | ||
UL Recognized | X | X | |||
UV Traceable | X | X | X | X | |
Coating Characteristics | |||||
Flexibility | 1 | 1 | 1 | 4 | 1 |
Solderability | 4 | 4 | 4 | 3 | 4 |
Repairability | 3 | 3 | 3 | 4 | 3 |
Dielectric Breakdown | 1100 | 1100 | 1100 | 8300 | 1100 |
Working Temperature | -85F to 390º (-65ºC to 200º) | -85F to 390º (-65ºC to 200º) | -85F to 390º (-65ºC to 200º) | -75F to 270º (-59ºC to 132º) | -85F to 390º (-65ºC to 200º) |
Cure Profile | |||||
Tack Free Time | 15 min | 15 min | 15 min | 30 min | 15 min |
Full Cure Time | 24 hrs @RT | 24 hrs @RT | 24 hrs @RT | 24 hrs @RT | 24 hrs @RT |